Body Scan

Blog

Body Scan

contamination-monitor health-physics

PRODUCT DESCRIPTION

Body Scan detectors: Choose the one that is best for you! Our detectors come with easy positioning by an userfriendly plug-in system. Moreover, the detector foils are easy to replace by the user, even by untrained personnel. For reliable and fast measurements, our detectors provide high efficiencies for alpha and beta radiation.

Project Details

FULL-BODY CONTAMINATION MONITOR

The Body Scan is used where the surface contamination of persons has to be monitored for a limit value. This is the case at the exit of operational control areas, e.g. in nuclear facilities.

The measuring task of the personal contamination monitor is to prove the exceeding of the limit value of the surface contamination with a high statistical certainty. In the case of non-contaminated persons, however, no contamination alarm should be generated with high statistical certainty.

HIGHLIGHTS

General

  • Suitable for α-, β- and γ-contamination measurements
  • Unsurpassed coverage of 20640 cm²
  • Robust stainless steel housing, easy decontamination, easy maintenance
  • Linux-based operating software
  • Remote monitoring (optional)
  • Very low background

Features

  • Automatically adjustable overhead detector, from 160 cm to 210 cm
  • QuickScan technology to reduce count times
  • Negligible dead zones between the individual detectors
  • User screens and voice prompts in user-selectable language

Measurement Mode

  • Background updates for all detectors every second
  • Automatic measuring time calculation
  • Presets for specific measuring times
  • User guidance through voice output
  • Display of contaminated areas
  • Measurements saved to an SQL database

Body Scan

Measurement Mode

The measurement principle is based on two steps for each person (front and back measurement). The optimized detector arrangement makes it possible to capture almost the entire surface of the person being measured. The person’s size is irrelevant. The head detector is automatically positioned and is secured by a light curtain. During measurement, the positions of the hands, feet, head and body are monitored constantly to prevent positioning errors. For easy handling, the touchscreen and detailed instructions over a speaker guide the user into the correct position. If no person or contamination is being measured, the background is automatically and continuously monitored. During measurement, the loudspeaker indicates the remaining measurement time and all measurement values are displayed at the same time. For alarms, various threshold values can be set. The measurement results can be shown in cps, Bq, and Bq/cm2, as desired.

TECHNICAL DATA

SZ 860 PLASTIC SCINTILLATION DETECTOR PDK 860 GAS FLOW PROPORTIONAL DETECTOR
Housing robust plastic housing robust aluminum housing
Transmission rate 83% 83%
Entry window dimensions 480 mm x 180 mm 480 mm x 180 mm
Active surface 860 cm² 860 cm²
Entry window material Mylar/PE Mylar/PE
Background α < 0.1 cps, β < 15 cps α < 0.1 cps, β < 10 cps
Dimensions 500 mm x 180 mm x 60 mm (L x W x H) 500 mm x 180 mm x 45 mm (L x W x H)
Weight approx. 1.2 kg approx. 1.4 kg
Mechanical Data
Dimensions & Weight (W x H x D) [mm]
Open cabinet 2400 x 750 x 1000, 300 kg
With doors 2400 x 1000 x 1300, 500 kg
With doors + gamma detectors + lead shielding 2400 x 1000 x 1300, 1500 kg
Material Stainless steel

Brochure