Radio-HPLC

The FlowCountPRO is a flexible and versatile radioisotope detection system specifically designed for High-Performance Liquid Chromatography (HPLC) applications. It supports the detection of a wide range of radionuclides and operates as a standalone device without the need for external software or a PC.

Key Features

Standalone Operation

Operates independently without requiring PC software, providing flexibility for real-time measurements.

Dual Detector Channels

Monitors two separate detectors simultaneously, making it efficient for multiple applications.

Touchscreen Interface

Equipped with an integrated touchscreen display for easy setup and monitoring of probes.

Wide Detector Compatibility

Supports various detectors including NaI/PMT, PIN diode, and plastic scintillator-based detectors for gamma, beta, and positron emitters.

HPLC Integration

Compatible with all chromatography data systems via variable voltage and pulse outputs, allowing seamless integration with existing setups.

Updateable System

The system can be updated using an SD card, ensuring that it remains up to date with the latest advancements.

Flexible Shielding and Flow Cells

Offers various lead shielding options and adjustable flow cells for detecting a wide range of isotope activities, from low to high energy emitters.

PET and Metabolite HPLC Detection

Capable of coincidence mode for PET metabolite detection using specialized detectors.

Customizable for Different Applications

The system can accommodate different isotopes, shielding, and flow cells, making it ideal for diverse applications in nuclear medicine, radiopharmaceutical analysis, and research.

Technical Specifications

Dimensions

190 mm (L) x 133 mm (W) x 94 mm (H) / 7.5” x 5.2” x 3.7”.

Weight

1.5 kg / 3.3 lbs.

Power Supply

Integrated power supply supporting multiple detector types.

Detector Options
FC-3100

NaI/PMT-based detector for low-energy gamma (10–60 keV), used primarily for ^{125}I

FC-3200

NaI/PMT-based detector for high-energy gamma (60–1500 keV), used in most nuclear medicine applications

FC-3300

NaI/PMT with well configuration for wide-range gamma detection and built-in lead shielding.

FC-3400 & FC-3500

PIN Diode detectors for high-count-rate applications with low sensitivity and compact design, supporting a linear range from 10 µCi to 1 Ci.

FC-3600

Plastic Scintillator/PMT-based detector for high-energy beta and positron emitters such as ^{32}P, ^{90}Y, ^{18}F, ^{11}C, and ^{13}N (>30 keV)

FC-4100

BGO/PMT detector for coincidence detection, especially for PET metabolite studies.

ADII CsI

CsI-based detector for high-energy gamma detection, with optional integration into the Modular-Lab HPLC system.

Flow Cells & Holders

Various lead-shielded holders and flow cells are available for high-activity gamma and PET isotope detection.

FC-4300

Detector holder with flow cell tubing adapter.

FC-5101 & FC-5102

Holders and flow cells for PMT detectors.

FC-5200 & FC-5250

Lead-shielded holders for high-activity gamma detectors.

FC-5260

Heavily shielded flow cell for PET isotopes, specifically designed for diode detectors.

Outputs

Variable voltage outputs (200 mV / 2 V) and pulse outputs (up to 500 kHz) for easy integration with HPLC systems.

Application

Radiopharmaceutical analysis for ^{99m}Tc, ^{111}In, ^{125}I, ^{131}I, ^{90}Y, and other isotopes.

PET tracer and metabolite analysis for isotopes like ^{68}Ga, ^{18}F, and ^{11}C.

Protein, DNA, and monoclonal antibody labeling and analysis with ^{32}P and ^{125}I.